Skip to main content
Product

The Soligrid Uptime Platform

RS485/Modbus data logging feeding a multi-tenant dashboard built for plant engineers and portfolio owners alike. Live performance, soiling loss, O&M workflows, and CFO-ready reporting in one place.

Platform

Four modules, one plant record

Each module reads from the same underlying data, so the number your engineer sees on the floor matches the number in the CFO's report.

  • 01

    Live Plant Performance

    Real-time generation, performance ratio, and inverter availability per plant, with drill-down to string and array level when a number looks wrong.

  • 02

    Soiling Loss Index

    A running estimate of output lost to soiling since the last clean, derived from performance drift against expected generation. It tells you when a clean has stopped paying for itself.

  • 03

    O&M Workflows and Ticketing

    Every alarm, inspection, and cleaning cycle becomes a tracked ticket with an owner and a close-out record, so nothing gets fixed off the books.

  • 04

    Reports for CFO/ESG

    Monthly and quarterly summaries built for people who don't want to open a dashboard: generation, uptime, avoided loss, and open issues in one document.

Inside the platform

One screen for the whole portfolio

A composite view of what a portfolio owner sees on login: aggregate performance, a generation trend, and per-plant status.

Portfolio Overview

4 plants · 4.65 MWp combined · Demo data

Demo data

81.5%

Avg. performance ratio

98.6%

Avg. uptime, 30d

3

Open tickets

Moderate

Soiling loss index

Generation vs. expected, last 14 days

PlantPerformance ratioUptime, 30dOpen tickets
Plant 01 · 800 kWp82.1%99.2%0
Plant 02 · 1.2 MWp81.3%98.4%1
Plant 03 · 650 kWp76.5%97.1%2
Plant 04 · 2.0 MWp85.9%99.6%0
The other three modules

Soiling, workflow, and reporting, all from the same data

What Soiling Loss Index, O&M Workflows, and CFO/ESG Reports actually look like when they're open.

Soiling Loss IndexModerate

Illustrative, demo data: estimated output lost to soiling since the last clean. Crosses the cleaning threshold at 45%.

O&M Workflow (demo data)1 new
  • Inverter offline · Plant 03open
    Alarm
  • Cleaning due · Plant 01, Array Cscheduled
    Cleaning
  • Combiner box inspectionin progress
    O&M
  • String anomaly resolved · Plant 04closed
    Alarm
CFO / ESG ReportMonthly

Portfolio Summary, March (demo data)

Generation vs. target96%
Portfolio uptime98.6%
Avoided loss (est.)recovered

Auto-generated on the first business day of each month, formatted for distribution without opening the dashboard.

Going further

An AI and analytics layer on top of the data

Every reading the gateway logs also feeds two more layers: an AI layer that flags patterns before a human would, and a deeper analytics layer for teams who want to go past the daily dashboard.

AI LayerBeta

Generated insight (demo data)

Confidence92%
Array C · Plant 03Soiling trendAction: schedule cleaning
Data Analytics Layer10-day view, demo data
Array A
Array B
Array C
Array D

Forecast, next 7 days

Under the hood

Built on standard industrial protocols

No proprietary sensors to force onto your plant. The platform speaks the same language your inverters already do.

  • RS485/Modbus data logging

    Direct integration with major inverter brands over RS485/Modbus, no proprietary hardware lock-in required on sites that already have compatible loggers.

  • Multi-tenant by design

    Built for portfolios from day one: role-based access for plant engineers, facility heads, and management, each seeing only what they need.

  • Alarms that reach a person

    PR-drop, inverter-offline, and string-anomaly alarms route to the assigned engineer, not just a dashboard nobody is watching.

  • Cleaning and maintenance tracking

    Every cleaning cycle and maintenance visit is logged against the plant record, so performance data and service history live in one place.

Hardware

One gateway, plugged in at the inverter

The platform needs a link to your inverters. This is it: a compact data gateway that plugs in at the inverter and reads its data over RS485/Modbus.

Every plant we bring onto the platform gets a gateway at the inverter. It reads performance data from the inverter and sends it to the Soligrid Uptime Platform. Nothing is installed in your electrical panel.

Protocols
RS485/Modbus
Connectivity
[SPEC TBC]
Mounting
At the inverter. Nothing is installed in your electrical panel.
Power
[SPEC TBC]

See the platform on your own plant

Connect a live feed or walk through a demo portfolio. Either way, we'll show you exactly what your team would see on day one.

Schedule an Uptime Audit